Explorium Logo

Beta Dyne Inc. logo

betadynepower.com

110 Elm Street, #12 Bridgewater, MA 02324, US

Beta Dyne Inc.

Beta Dyne is a leader in providing low-to-mid-range power solutions to the medical, industrial, telecomm, and instrumentation markets. We provide both standardized and custom solutions to meet the power needs of customers worldwide. We design, manufacture, and support all of our products from our facilities in the USA.

Beta Dyne Inc. logo

Beta Dyne Inc.

Beta Dyne is a leader in providing low-to-mid-range power solutions to the medical, industrial, telecomm, and instrumentation markets. We provide both standardized and custom solutions to meet the power needs of customers worldwide. We design, manufacture, and support all of our products from our facilities in the USA.

betadynepower.com

110 Elm Street, #12 Bridgewater, MA 02324, US

Details

Year founded

1994

Revenue

500K-1M

Employees

1-10

Number of locations

1

NAICS

335

SIC

3630

Products & Services

Outlines the company's specialized services and operational strengths.

  • AC/DC power supplies
  • Converters
  • DC/DC power supplies
  • Contact us in order to access

Equipment

Provides a detailed list of machinery and tools utilized on the company's premises.

  • PD-65A MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) INPUT INRUSH CURRENT (Typ.) LEAKAGE CURRENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSION OTHERS
  • MQF240E SERIES 240 Watts Voltage (Note 4) 90-264 VAC Frequency (Hz) 47-63 Hz Current (Full load) < 3.0 A max. (115 VAC) / < 1.5 A max. (230 VAC) Inrush Current (<2ms) < 45 A max. (115 VAC) / < 90 A max. (230 VAC) Leakage Current < 0.1mA / 264 VAC (Touch Current) Input Power Factor PF>0.9 at Full Load Voltage (V.DC.) 12V 24V 48V Voltage Adj Range (V.DC.) ±4% Output Voltage Voltage Accuracy ±2% Current max 20 10 5 Line Regulation ±1% Load Regulation (0-100%) ±1% Minimum Load 0% Maximum Capacitive Load 8000µF 3000µF 470µF Ripple & Noise max. (Note 1) 1% Vout Efficiency (at 230VAC) (Note 6) 92% 92.5% 93% Output Hold-up Time (at 115 VAC) (Note 2) 10 ms min. Over Power Protection Auto recovery, Hiccup mode Over Voltage Protection Zener diode clamp Overt Temperature Protection Auto recovery Protection Short Circuit Protection Auto recovery, Hiccup mode Input-Output 4000VAC or 5656VDC Input-FG 2000VAC or 2828VDC Isolation Output-FG 1500VAC or 2121VDC Operating Temperature -30°C…+70°C (with derating) Storage Temperature -30°C…+85°C Temperature Coefficient ±0.05%/°C Humidity 20~90% RH MTBF >250,000 h @ 25°C (MIL-HDBK-217F, Notice 1) Environment Vibration 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y , Z axes. Dimension (L x W x H) 4.1 x 2.44 x 1.95 Inches (104 x 62.0 x 49.5 mm) Tolerance 0.5 mm Weight Physical Cooling Method Free convection
  • MPU60A series 63W External Medical Grade Power Supply Wide Operating Voltage, 80 to 275 VAC, 47 to 63 Hz IEC-320-C14 Input Inlet Other Input/Output Configurations Available (contact Beta Dyne Sales ) Single Output (Factory set, contact Beta Dyne Sales for other Voltage options) Crowbar Mode Over Voltage Protection Input to Output : 2MOPP High ESD immunity Suitable professional healthcare facility Class I system 5 year warranty
  • Contact us in order to access

Ramping up production

Indicates the company's current production trend and growth trajectory.

TRUE

Our production algorithm is showing that beta dyne is ramping up production.

Target industries

Medical
Industrial
Electronics

Employees working in Beta Dyne Inc.

Anastasios Simopoulos

President

Anastasios Simopoulos

President

Tassos Simopoulos

President

Nikie Fikis

Vice president of sales

Harry Canellos

Vice president of manufacturing

Employees working in Beta Dyne Inc.

Anastasios Simopoulos

President

Anastasios Simopoulos

President

Tassos Simopoulos

President

Nikie Fikis

Vice president of sales

Harry Canellos

Vice president of manufacturing

Fikis Nikie

Vice president of sales and buyer

Betsey Oldham

Director of sales and marketing

Book a demo

Locations (1)

Beta Dyne Inc.

110 Elm Street, #12 Bridgewater, MA 02324, US

Frequently Asked Questions


Beta Dyne Inc. offers a range of services and capabilities, including AC/DC power supplies.


Get the full services & capabilities list of Beta Dyne Inc.

Beta Dyne Inc. uses a variety of equipment, including PD-65A MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) INPUT INRUSH CURRENT (Typ.) LEAKAGE CURRENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSION OTHERS.


Get the full equipment list of Beta Dyne Inc.

Beta Dyne Inc. serves several industries, including the medical industry.


Get the full target industries list of Beta Dyne Inc.

Beta Dyne Inc. operates from a single location at 110 elm street #12, bridgewater, massachusetts 02324, united states.


Get a free locations and target markets review for Beta Dyne Inc.

The headquarters of Beta Dyne Inc. are located in 110 elm street #12, bridgewater, massachusetts 02324, united states.


Get a free locations and target markets review for Beta Dyne Inc.

The NAICS code for Beta Dyne Inc. is 335.


Get a free business data review for Beta Dyne Inc.

Beta Dyne Inc. has 8 employees.


Get a free workforce data review of Beta Dyne Inc.

The official website of Beta Dyne Inc. is https://www.betadynepower.com/.


Beta Dyne Inc. was founded in 1994.